System components | |
---|---|
Emitter | SLP65-2-T |
Receiver | SLPC65-2-R |
General specifications | |
Effective detection range | 12 ... 65 m |
Light source | LED |
Light type | modulated visible red light |
Safety type according to IEC/EN 61496 | 4 |
Marking | CE |
Target size | static: 32 mm dynamic: 50 mm (at v = 1.6 m/s of the obstacle) |
Beam spacing | 500 mm |
Number of beams | 2 |
Operating mode | Start/restart disable, relay monitor, |
Angle of divergence | < 5 ° |
Functional safety related parameters | |
Performance level (PL) | PL e |
Category | Cat. 4 |
Mission Time (TM) | 20 a |
PFHd | 3.54 E-9 |
Indicators/operating means | |
Diagnostics indicator | 7-segment display |
Function indicator | LED red: per receiver channel off: interruption flashes: receiver continuously on: reception with sufficient stability control on the front plate: LED red: OSSD off LED green: OSSD on |
Pre-fault indicator | LED red next to receiver flashes |
Electrical specifications | |
Operating voltage | 2Или отправьте нам запрос наalvanically isolated |
Input | |
Function input | Relay monitor, start release |
Output | |
Safety output | 2 separated fail safe semiconductor outputs |
Signal output | 1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off |
Switching voltage | Operating voltage -2 V |
Switching current | max. 0.5 A |
Conformity | |
Functional safety | ISO13849-1 |
Product standard | EN61496-1 ; IEC61496-2 |
Mechanical specifications | |
Degree of protection | IP65 |
Connection | M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitter |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |