General specifications | |
---|---|
Switching function | Normally closed (NC) |
Output type | Two-wire |
Rated operating distance | 8 mm |
Installation | non-flush |
Output polarity | AC |
Assured operating distance | 0 ... 6.48 mm |
Actual operating distance | 7.2 ... 8.8 mm typ. 8 mm |
Reduction factor rAl | 0.4 |
Reduction factor rCu | 0.4 |
Reduction factor r304 | 0.7 |
Nominal ratings | |
Operating voltage | 20 ... 253 V |
Switching frequency | 0 ... 20 Hz |
Hysteresis | typ. 7.5 % |
Reverse polarity protection | reverse polarity tolerant |
Voltage drop | < 5 V (IL > 50 mA); < 8 V (IL < 50 mA) |
Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA |
Operating current | 5 ... 200 mA |
Off-state current | 0 ... 1.7 mA typ. |
Operating voltage indicator | LED, green |
Switching state indicator | LED, yellow |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications | |
Connection type | Connector 1/2"-20 UN , 3-pin |
Housing material | brass, nickel-plated |
Sensing face | PBT |
Housing diameter | 18 mm |
Degree of protection | IP67 |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse ? 0.8A (quick-blow) according to IEC60127-2 Sheet1 Recommendation: after a short circuit, check that the device is functioning correctly. |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |